Руководство по установке блока питания APC Back-Line-R LE600I в формате PDF

Форум РадиоКот • Просмотр темы – схема UPS APC1500

Сб фев 07, 2015 00:15:34

Сб фев 07, 2015 06:56:34

Хотя-бы с качественных фотографий внутренностей.

Сб фев 07, 2015 07:20:04

Что именно сфотографировать??? Там всего-то MAIN PCB, транс и блок АКБ. Может на плате какой-то узел конкретно???

Сб фев 07, 2015 07:26:05

Сб фев 07, 2015 07:49:40

MAIN PCB.jpg

(242.86 KiB) Скачиваний: 803

Сб фев 07, 2015 08:05:38

Сб фев 07, 2015 08:33:33

Сб фев 07, 2015 11:30:23

Сб фев 07, 2015 12:03:56

Пт апр 17, 2015 23:04:48

phpBB Mobile / SEO by Artodia.

The APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags, and surges from reaching your computer and other valuable electronic equipment. The UPS filters small utility line fluctuations and isolates your equipment from large disturbances by internally dis-connecting from the utility line. The UPS provides continuous power from its internal battery until the utility line returns to safe levels or the battery is discharged.

Read the Safety Instruction sheet before installing the UPS.

Inspect the UPS upon receipt. A PC designed robust packaging for your product. However, accidents and damage may occur during shipment. Notify the carrier and dealer if there is damage.

The packaging is recyclable; save it for reuse or dispose of it properly.

Check the package contents. The package contains the UPS, the front bezel, the rail kit, and a litera-ture kit containing:

Serial and USB communication cables

Two IEC jumper cables and one plug adaptor (230V models only)

Mounting rails are supplied for the standard 4-post rack. Two-post racks require only the mounting brackets.

1.  Standard 2.  Optional (1.4″ setback) 3.  2-post rack (5″ setback)

Сразу прошу прощения за свою неграмотность. Сам я системный администратор, и ремонтом занимаюсь в качестве хобби.
Предыстория такая: APC Smart-UPS 1000 долгие годы работал в серверной, пока не начал неадекватно себя вести – перестал сам включаться при появлении напряжения в сети. При включении тоже, иногда мигал что-то непонятное лампочками и пищал.
Было решено заменить его на запасной.
Выключил, отсоединил все провода, вытащил батарею и убрал на полочку потому как на тот момент возиться с ним времени не было.
Прошло пол года и я решил-таки его поковырять.

Снова разобрал, проверил подключение всех проводов, полярность электролитов, прозвонил шлейф, который идет к панельке с кнопками – всё в норме.

Подозрение пало на реле RY4 o/e/n 68-24-2AE, которое как раз-таки должно щелкать при подаче питания (думал, может контакты залипли). Выпаял, подал на обмотку 24В – нормально щелкает, сопротивления в норме. Т.к. заменить было не чем, для эксперимента поменял его местами с RY7 (реле одинаковые), которое стоит на выходе ИБП.

Включаю в сеть – реле молчат. Замеряю напряжения на обмотках релюшек – везде понулям.
Проверяю напряжение на всех мелких электролитах – так же по нулям.

То есть, если я правильно понял, вообще не работает “дежурный источник питания” (по аналогии с ATX-блоками питания).
Напряжение ~220В на входе платы присутствует и доходит до первичной обмотки трансформатора T1. Ко вторичной обмотке подключен D18 – маленькая трехлапая деталька в корпусе SOT23, как я понял это диодная сборка с двумя встречно подключенными диодам. Дальше пока смотреть не стал, т.к. плата двусторонняя и не было схемы.

Больше всего удивило, что он до последнего момента работал, и перестал работать сразу после моего “ремонта”.
Внимательно осмотрел плату, smd-элементы вроде нигде не сбиты, никаких повреждений. Перемычка на текстолите помеченная как F1 F1A – целая.

Что делать? Тупо идти по схеме от трансформатора T1 и прозванивать всё что можно?

На всякий случай, прикрепил схему, которую нашел. Более-менее похожа на мой ИБП.

1. Подключите оборудование к ИБП. Примечание. Не подключайте лазерный принтер к ИБП. Лазер

принтер потребляет значительно больше энергии, чем другие типы оборудования, и может привести к перегрузке ИБП.

2. Добавьте любые дополнительные аксессуары в Smart-Slot.

3. С помощью шнура питания подключите ИБП только к двухполюсной, трехпроводной, заземленной розетке.

Избегайте использования удлинителей.

Модели на 100/120 В: шнур питания постоянно прикреплен к задней панели ИБП. Разъем INPUT — это NEMA 5-15P.

Модели на 230 В: шнур питания предоставляется заказчиком. Подсоедините провода заземления к винту TVSS (дополнительно). Чтобы выполнить подключение, ослабьте винт и подсоедините провод заземления устройства подавления перенапряжения. Затяните винт, чтобы закрепить провод.

4. Включите все подключенное оборудование. Чтобы использовать ИБП в качестве главного переключателя ВКЛ/ВЫКЛ, убедитесь, что все кон-

подключенное оборудование включено. Оборудование не будет получать питание, пока не будет включен ИБП.

5.  Чтобы включить ИБП, нажмите кнопку

на передней панели.

ИБП заряжает аккумулятор, когда он подключен к сети. Аккумулятор заряжается до 90% емкости в течение первых четырех часов нормальной работы. Не ожидайте полной работоспособности батареи в течение этого начального периода зарядки.

Модели на 120 В: проверьте светодиодный индикатор неисправности электропроводки, расположенный на задней панели. Он загорается, если ИБП подключен к неправильно подключенной сетевой розетке. См. Устранение неполадок в этом руководстве.

:/>  ITunes требует Windows 10 — как установить на Windows 7 и 8?

6.  Для дополнительной безопасности компьютерной системы установите PowerChute

С ИБП можно использовать программное обеспечение для управления питанием и наборы интерфейсов. Используйте только наборы интерфейсов, поставляемые или одобренные компанией APC.

Используйте кабель из комплекта поставки APC для подключения к последовательному порту. НЕ используйте стандартный кабель последовательного интерфейса, так как он несовместим с разъемом ИБП. Предусмотрены как последовательные, так и USB-порты. Их нельзя использовать одновременно.

ИБП оснащен винтом для подавления перенапряжения при переходных процессах (TVSS) для подключения заземляющего провода к устройствам для подавления перенапряжения, таким как устройства защиты телефонных и сетевых линий. При подключении заземляющего кабеля отключите ИБП от сети.

Всем доброго времени суток. Пришел в ремонт такой встречак. Надпись на процессоре PD7732-Z-0001B-001 UPS REV.3 SMART-UPS 3.6 G 2004 APCC. При подключении батареи только щелкало реле и ничего не возбуждалось – никакие напряжения на плате не поднимались – ну дежурные . При первичном осмотре нашел пробитые Q42 Q44 – дырочки в них, а также рядом Q301- не понравилось по замерам. Поменял все 3 транзистора. Также оказался пробитый R212 – заменен. Все электролиты были поменяны до меня кем то. Правда на 22 мкф стояли на 16 вольт,заменил на положенные 25 вольт. Также наблюдается один участок с коррозией платы – поотгнивал кой где дорожки от пятаков. Восстановил. При включении – в первый раз упс начал тонул – но как то странно – загорелся индикатор работа от сети работа от батареи и одна лампочка на зарядке батареи. Напряжение на выходе очевидной внешности – 230 вольт примерно. Выключил обнаруженик – подключил шнур от сети 220 вольт на входе – сразу приличный гул трансформатора – на проводах напряжения от напряжения постоянное 28 вольт – возможно, зарядит плотность. Отключенная батарея – 26 вольт. . Потом долго жму на настройку старт -предупреждает запустится – безуспешно – в динамике писк. Проверил все реле – не выпаивая из платы – дал лабораторника на катушку 24 вольта. Вроде отработали все штатно. Сначала нормально замкнутые, при подаче 24 вольта – одни размыкались – другие что надо замыкались – не знаю правилен ли такой способ проверки – или надо как то иначе их тестить – ну мож замена – везде пишут,что емкостя 22мкф и реле – это больное место данных упсов. Также проверил все мосфеты на плате – прозвонкой – все вроде в норме. Напряжения + 5вольт +12 вольт минус 9 вольт присутствуют – ну от шима 3843. Напряжение питания проца – 5 вольт от линейного стаба – также в норме. В общем даже когда упс и включался – раза с 10-го – норм он не работал – даже при подключенном внешнем шнуре 220 вольт на табло – работа от батареи, мигает работа от сети и писк постоянный а не 4 раза – как вроде должно при работе от батареи. Прошивал разные прошивки в 93C56 – стабильной работы достичь не удалось – с одной из прошивок он гарантированно включался начинал работу – но через секунд 10 вспыхивал индикатор перегруз – и упс отключался. Нашел на remaud прошивку точно под ремонтируемый упс – человек пишет что слит с рабочего,проверен лично – заливкой в другой такой же упс. К положительному результату это также не привело. А именно

– подключена только батарея – нажимаю старт – клацает раз реле опять клацает – писк пару секунд – упс не включается -все напруги на плате есть – светодиод зеленый сзади горит на кнопку выкл – реагирует данную операцию проводил и от лабораторника – вместо батареи давал 24 в 25 в 26 в 27 в 28 в – без изменений

– при подключенной батарее – подключаю сетевой шнур – клацает реле раз потом еще раз – упс не включается. При нажатии на кнопку старт – через пару секунд писк – длительностью пару секунд – упс не включается. – на кнопку отключения – упс не реагирует. Напряжение – переменное на выходе – 12.8 вольт Напряжение на проводах от батареи – 28 вольт – тип идет заряд – раза с двадцатого упс включился – без сетевого питания если – на табло – работа от батареи,горит один индикатор уровня заряда батареи. упс сигнализирует штатно вроде – 4 писка через примерно 30 секунд – типа работа от батареи

Подскажите,кто знает – что еще проверить,ну или хотя бы в каком узле может быть проблема.

Thank you for purchasing APC by Schneider Electrics Line-R Automatic Voltage Regulator! Fill out and mail the product warranty registration form, or fill out an online form at www.apc.com.

:/>  cmd - Net Send command in Windows 10 Home Edition - Stack Overflow

The Line-R automatically corrects brownouts (by boosting low voltage) and overvoltages (by stepping down high voltage) from the power utility service to levels that are safe for computers, as well as other sensitive equipment. A PC by Schneider Electrics Line-R provides the highest degree of protection from line voltage sags and swells, and has been designed for many years of reliable, maintenance-free service.

The Line-R is designed for use with voltage sensitive equipment such as a: computer, monitor, inkjet printer, scanner or fax. It is also designed for use with home electronics (TVs, stereos, CD players, etc.). Appliances not suitable for use with the Line-R are items such as refrigerators, freezers, power tools, air conditioners, dehumidifiers, blenders, or any device that employs an AC motor for operation. Not for use with life sustaining equipment and any device with a power requirement exceeding the Maximum Output Power Capacity rating listed in the Specifications table.

Power Switch The Line-R provides a front panel power switch (l = on) / (O = off) which functions as the master power switch for the Line-R and all devices connected to the device.

Push Button Circuit Breaker The Line-R provides a push button circuit breaker on the rear panel of the unit to protect it from being overloaded. If the circuit breaker trips, unplug the last device connected to the unit and push the circuit breaker fully inward.

NOTICE RISK OF EQUIPMENT DAMAGE

The total power consumption of all equipment plugged into the Line-R must not exceed the ratings listed in the Specifications table below. A total load in excess of the listed ratings will cause the push button circuit breaker to trip.

Automatic Voltage Regulator Models LE600I and LE1200I

Lights when input voltage is high.

Flashes when input voltage is above rated Input Voltage Range.

Input voltage is normal.

Lights when input voltage is low.

Flashes when input voltage is below rated Input Voltage Range.

The power switch applies and removes power to/ from the Line-R (l = on) / (O = off).

Розетки переменного тока

(подключить оборудование здесь)

(см. Выбор входного напряжения) Кнопка

Подключите съемное устройство

Шнур питания здесь и к настенной розетке переменного тока

Подсоедините прилагаемый шнур питания от любой розетки к вашему

Установка Размещение – Устанавливайте Line-R в защищенном месте, свободном от пыли,

механическая вибрация, горючие газы и взрывоопасная или агрессивная атмосфера.

Включите Line-R в настенную розетку. Отсоедините кабель питания компьютера от задней панели компьютера и подключите Line-R к настенной розетке. Используйте один из двух шнуров питания, поставляемых с Line-R, для повторного подключения компьютера к любой из четырех розеток на задней панели Line-R. Line-R следует использовать только в зданиях, имеющих надлежащее заземление на ответвленной цепи, защищенной предохранителем или автоматическим выключателем.

Подключите оборудование. Подключите оборудование к розеткам Line-R на задней панели и включите его. Оборудование не будет получать питание до тех пор, пока Line-R не будет включен.

Включите Line-R – Переведите выключатель питания на передней панели в положение включения (l). Этот переключатель можно использовать в качестве главного переключателя для устройства и всего подключенного к нему оборудования.

Технические характеристики Характеристики Модель LE600I Модель LE1200I

Максимальная выходная мощность 600 Вт или 600 ВА 1200 Вт или 1200 ВА

Номинальный входной ток 2,6 А 5,2 А

Допуск допустимого диапазона напряжения 160–270 В (селекторный переключатель установлен на 220 В)

166–280 В (селекторный переключатель установлен на 230 В)

170–290 В (селекторный переключатель установлен на 240 В)

Номинальное входное напряжение 250 В переменного тока

Максимально допустимое входное напряжение 300 В

Импульсная энергия 300 Дж

Регулирование выхода 10%

Время отклика < 2 циклов переменного тока

Номинальная частота 47 – 63 Гц

Количество торговых точек 4

Рабочая температура 32–104F (0–40C)

Относительная влажность 0–95 % без конденсации

Размеры 4,6 x 8,4 x 5,5 дюймов (118 x 214 x 141 мм)

Вес 3,1 кг (6,8 фунта) 4,2 кг (9,2 фунта)

Ограниченная гарантия Компания Schneider Electric IT (SEIT) гарантирует отсутствие в своей продукции дефектов материалов и изготовления в течение двух

лет с даты покупки. Обязательства компании по данной гарантии ограничиваются ремонтом или заменой, по ее собственному выбору, любых таких дефектных изделий. Чтобы получить обслуживание по гарантии, вы должны получить номер разрешения на возврат материалов (RMA) в SEIT или в сервисном центре SEIT. Продукты должны быть возвращены в SEIT или сервисный центр SEIT с предоплатой транспортных расходов и должны сопровождаться кратким описанием возникшей проблемы и подтверждением даты и места покупки. Настоящая гарантия не распространяется на оборудование, которое было повреждено в результате несчастного случая, небрежности или неправильного использования либо было каким-либо образом изменено или модифицировано. Настоящая гарантия распространяется на первоначального покупателя, который должен надлежащим образом зарегистрировать продукт в течение 10 дней с момента покупки.

:/>  Управление групповыми политиками в организации. Часть 6

ЗА ИСКЛЮЧЕНИЕМ СЛУЧАЕВ, ПРЕДУСМОТРЕННЫХ ЗДЕСЬ, SEIT НЕ ПРЕДОСТАВЛЯЕТ НИКАКИХ ЯВНЫХ ИЛИ ПОДРАЗУМЕВАЕМЫХ ГАРАНТИЙ, ВКЛЮЧАЯ ГАРАНТИИ КОММЕРЧЕСКОЙ ПРИГОДНОСТИ И ПРИГОДНОСТИ ДЛЯ ОПРЕДЕЛЕННОЙ ЦЕЛИ. В некоторых странах не допускается ограничение или исключение подразумеваемых гарантий; следовательно, вышеуказанные ограничения или исключения могут не применяться к покупателю.

ЗА ИСКЛЮЧЕНИЕМ ВЫШЕУКАЗАННОГО, НИ ПРИ КАКИХ ОБСТОЯТЕЛЬСТВАХ НЕ НЕСЕТ ОТВЕТСТВЕННОСТИ ЗА ПРЯМОЙ, КОСВЕННЫЙ, СПЕЦИАЛЬНЫЙ, СЛУЧАЙНЫЙ ИЛИ КОСВЕННЫЙ УЩЕРБ, ВОЗНИКШИЙ В РЕЗУЛЬТАТЕ ИСПОЛЬЗОВАНИЯ ДАННОГО ПРОДУКТА, ДАЖЕ ЕСЛИ УВЕДОМЛЕНО О ВОЗМОЖНОСТИ ТАКОГО УЩЕРБА. В частности, SEIT не несет ответственности за какие-либо расходы, такие как упущенная выгода или доход, потеря оборудования, невозможность использования оборудования, потеря программного обеспечения, потеря данных, затраты на замену, претензии третьих лиц или иное. Эта гарантия дает вам определенные юридические права, и вы также можете иметь другие права, которые могут различаться в зависимости от местоположения.

APC by Schneider Electric ИТ-поддержка клиентов по всему миру Для получения поддержки клиентов в конкретной стране перейдите по ссылке

Благодарим вас за покупку автоматического регулятора напряжения APC Line-R! Пожалуйста, заполните и

, а также другое чувствительное оборудование. Line-R ПК обеспечивает наивысшую степень защиты

ВНИМАНИЕ: Суммарная потребляемая мощность всего оборудования, подключенного к Line-R, не должна

превышают рейтинг «Максимальная выходная мощность», указанный в таблице «Технические характеристики». Всего

нагрузка, превышающая этот номинал, приведет к «отключению» автоматического выключателя.

, превышающий показатель «Максимальная выходная мощность», указанный в таблице «Технические характеристики».

перегружены. Если автоматический выключатель «срабатывает», отключите последнее устройство, подключенное к блоку, и

w w w.apc.com

к розетке переменного тока

Выключатель питания включает и отключает питание/

Шнур питания от любого

Выход на ваше устройство

• Размещение. Пожалуйста, устанавливайте Line-R в защищенном месте, свободном от пыли,

• Включите Line-R в настенную розетку. Отсоедините кабель питания компьютера от задней панели

.

Переключатель регулировки входного напряжения для региона использования (пример: Россия

– 220В, Дания – 230В, Великобритания – 240В). Сдвиньте переключатель, чтобы выбрать правильный

напряжение для вашего местоположения.

Подключите оборудование — подключите оборудование к розеткам Line-R на задней панели и включите оборудование-

ВНИМАНИЕ: Суммарная потребляемая мощность всего оборудования, подключенного к Line-R, не должна превышать

кнопочный автоматический выключатель на «отключение».

Номинальное выходное напряжение

32–104°F (0–40°C)

American Power Conversion (APC) гарантирует отсутствие дефектов материалов в своей продукции

и качество изготовления сроком на два года с момента покупки. Его обязательство по этому

номер от APC или сервисного центра APC. Продукты должны быть возвращены в APC или APC

ЗА ИСКЛЮЧЕНИЕМ ПРЕДУСМОТРЕННОГО ЗДЕСЬ, АМЕРИКАНСКОЕ ПРЕОБРАЗОВАНИЕ ЭЛЕКТРОЭНЕРГИИ НЕ ДАЕТ

ЗА ИСКЛЮЧЕНИЕМ ВЫШЕУКАЗАННОГО, APC НИ ПРИ КАКИХ ОБСТОЯТЕЛЬСТВАХ НЕ НЕСЕТ ОТВЕТСТВЕННОСТИ ЗА

ВОЗМОЖНОСТЬ ТАКОГО ПОВРЕЖДЕНИЯ. В частности, APC не несет ответственности за какие-либо расходы, такие как

Европа, Ближний Восток и Африка

APC и Line-R являются зарегистрированными товарными знаками компании American Power Conversion.

Все остальные товарные знаки являются собственностью соответствующих владельцев.

+353 91 702020

Руководство по установке блока питания APC Back-Line-R LE600I в формате PDF

Благодарим вас за покупку APC от Schneider Electric Line-R Automatic Voltage

, а также другое чувствительное оборудование. ПК от Schneider Electric Line-R обеспечивает самое высокое

Line-R имеет выключатель питания на передней панели (l )(O), который функционирует как

вызывают «срабатывание» кнопочного автоматического выключателя.

от Line-R l/O

• Размещение – Устанавливайте Line-R в защищенном месте, свободном от пыли,

• Включите Line-R в настенную розетку. Отсоедините шнур питания компьютера от

• Подключите оборудование — подключите оборудование к розеткам Line-R на задней панели и выключателю

• Включите Line-R – Переведите выключатель питания на передней панели в положение включения (l). Этот переключатель

Номинальный входной ток 2,6 А 5,2 А

Регулировка выхода ±10%

Рабочая температура 32–104°F (0–40°C)

Вес 3,1 кг (6,8 фунта) 4,2 кг (9,2 фунта)

Для получения поддержки клиентов в конкретной стране посетите веб-сайт APC by Schneider Electric, www.apc.com.

Electric Industries S.A.S. или их дочерние компании. Все остальные товарные знаки являются собственностью соответствующих